609176002016000 [KYOCERA AVX]
PCB Connector;型号: | 609176002016000 |
厂家: | KYOCERA AVX |
描述: | PCB Connector PC 连接器 连接器支架 |
文件: | 总8页 (文件大小:319K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SSL - Discrete Wire IDC
Series 9176
The 917X series of surface mount Insulation Displacement Connectors (IDC)
were developed to meet the harsh automotive and industrial market
applications for connecting individual wires directly to a PCB ranging from 14
AWG to 28 AWG. This industry proven contact system has been tested to
automotive levels of shock, vibration, and temperature cycling to prove their
reliability and robustness. The simplicity of inserting a wire into the connector
with a small tool allows a wide range of devices to be connected to the PCB
without soldering. In SSL applications specifically, these connectors are used to
bring power and signal onto the PCB or are used to daisy chain multiple boards
together in a long string. While the IDC contact provides a gas-tight connection
to conductor of the wire, the housing has been designed to grab the insulation
of the wire to provide a positive strain relief even in the harshest conditions. In
case of repair, the wires can be removed and replace up to three times.
The 9176 series accepts 18 AWG to 24 AWG wires with an insulation diameter
ranging from 1.1mm to 2.1mm. These dual contact connectors support a 10
amp current rating with two large SMT solder tails per wire to provide maximum
stability on the PCB. Available in 1p-3p configuration, these connectors can be
end stackable for higher pin counts. The 9176 series also comes with optional
locking strain relief caps that act as the termination tool for severe vibration
applications.
APPLICATIONS
FEATURES AND BENEFITS
• Connecting discrete wire components
directly to the PCB
• Bringing power and signals onto a PCB
• Daisy chaining PCB’s together to create
a continuous string of boards
• IDC contact provides a gas-tight connection to the PCB for long term reliability
•
•
Connector housing captures the wire insulation for positive strain relief
Tested to automotive levels on shock, vibration and temperature cycling for
reliability
•
•
•
•
Low and high volume assembly tools to match production volumes
Reduced total applied cost versus solder or crimp processes
Optional thru and end caps lock in place to provide maximum strain relief
High temperature insulator capable to 260ºC reflow soldering processes
• Application Notes: refer to 201-01-124
ELECTRICAL
ENVIRONMENTAL
MECHANICAL
• Current Rating: 10 Amp / Contact
• Voltage Rating: 250 VAC
• Operating Temperature:
-40ºC to +125ºC
• Insulator Material: Nylon 46: UL94V0
• Contact Material: Phosphor Bronze
• Plating: Tin over Nickel
• Durability: 3 Cycles
HOW TO ORDER
00X
00X
X
06
00
9176
Number of Ways
No of
Wire Gauge Size
Insulator Color
Plating
Option
06 = Pure Tin
all over
Prefix
Series
Code Color Application
Code
Accepted
Wire Gauge
Wire
Cap Code
Code
Details
Ways
Insulation Pages 47-48
0
1
Black
White
Industrial
Lighting
001
002
003
1
2
3
Page 44
Page 45
Page 46
001 18 Gauge Stranded Ø 1.6-2.1
011 20 Gauge Stranded Ø 1.6-2.1
022 22 Gauge Stranded Ø 1.1-1.6
032 24 Gauge Stranded Ø 1.1-1.6
021
021
016
016
Certification: UL File #E320991
43
SSL - Discrete Wire IDC
Series 9176
18-24 AWG 1 WAY IDC CONNECTOR
NOTES:
1. CONNECTOR FOR IDC WIRE TO BOARD CONNECTION.
2. CONTACT MATERIAL: PHOSPHORE BRONZE.
INSULATION MATERIAL: HIGH TEMPERATURE NYLON 46.
COLOR REFER TO PAGE 43.
3. CONNECTOR DESIGNED TO ACCEPT BETWEEN 24 AND 18 GAUGE
STRANDED WIRE.
4. ALL DIMENSIONS FOR REFERENCE UNLESS OTHERWISE STATED.
5. FOR FULL PRODUCT SPECIFICATION REFER TO ELCO SPEC 201-01-106 AND
APPLICATION NOTES 201-01-124.
6. FOR PCB SPACE RESTRICTED BY WIRE ASSEMBLY TOOLING REFER TO PAGE 47.
7. FOR HAND WIRE ASSEMBLY TOOLING REFER TO PAGE 49.
Code
Accepted
Wire Gauge
A
Wire
Insulation
B
001 18 Gauge Stranded 0.72 Ø 1.6-2.1 2.1
011 20 Gauge Stranded 0.60 Ø 1.6-2.1 2.1
022 22 Gauge Stranded 0.47 Ø 1.1-1.6 1.6
032 24 Gauge Stranded 0.37 Ø 1.1-1.6 1.6
SMT PCB LAYOUT
PURE TIN PADS
PACKING DETAILS
REEL QTY
LEADER
TRAILER
1000
480MM
120MM
44
SSL - Discrete Wire IDC
Series 9176
18-24 AWG 2 WAY IDC CONNECTOR
NOTES:
1. CONNECTOR FOR IDC WIRE TO BOARD CONNECTION.
2. CONTACT MATERIAL: PHOSPHORE BRONZE.
INSULATION MATERIAL: HIGH TEMPERATURE NYLON 46.
COLOR REFER TO PAGE 43.
3. CONNECTOR DESIGNED TO ACCEPT BETWEEN 24 AND 18 GAUGE STRANDED WIRE.
4. ALL DIMENSIONS FOR REFERENCE UNLESS OTHERWISE STATED.
5. FOR FULL PRODUCT SPECIFICATION REFER TO ELCO SPEC 201-01-106 AND APPLICATION
NOTES 201-01-124.
6. FOR PCB SPACE RESTRICTED BY WIRE ASSEMBLY TOOLING REFER TO PAGE 47.
7. FOR HAND WIRE ASSEMBLY TOOLING REFER TO PAGE 49
8. FOR PRESS WIRE ASSEMBLY TOOLING REFER TO PAGE 50.
9. FOR ACCESSORY CAPS REFER TO PAGES 47 AND 48.
Code
Accepted
Wire Gauge
A
Wire
Insulation
B
001 18 Gauge Stranded 0.72 Ø 1.6-2.1 2.1
011 20 Gauge Stranded 0.60 Ø 1.6-2.1 2.1
022 22 Gauge Stranded 0.47 Ø 1.1-1.6 1.6
032 24 Gauge Stranded 0.37 Ø 1.1-1.6 1.6
SMT PCB LAYOUT
PURE TIN PADS
PACKING DETAILS
REEL QTY
LEADER
TRAILER
1000
480MM
120MM
45
SSL - Discrete Wire IDC
Series 9176
18-24 AWG 3 WAY IDC CONNECTOR
NOTES:
1. CONNECTOR FOR IDC WIRE TO BOARD CONNECTION.
2. CONTACT MATERIAL: PHOSPHORE BRONZE.
INSULATION MATERIAL: HIGH TEMPERATURE NYLON 46.
COLOR REFER TO PAGE 43.
3. CONNECTOR DESIGNED TO ACCEPT BETWEEN 24 AND 18 GAUGE STRANDED WIRE.
4. ALL DIMENSIONS FOR REFERENCE UNLESS OTHERWISE STATED.
5. FOR FULL PRODUCT SPECIFICATION REFER TO ELCO SPEC 201-01-106 AND APPLICATION
NOTES 201-01-124.
6. FOR PCB SPACE RESTRICTED BY WIRE ASSEMBLY TOOLING REFER TO PAGE 47.
7. FOR HAND WIRE ASSEMBLY TOOLING REFER TO PAGE 49
8. FOR PRESS WIRE ASSEMBLY TOOLING REFER TO PAGE 50.
9. FOR ACCESSORY CAPS REFER TO PAGES 47 AND 48.
Code
Accepted
Wire Gauge
A
Wire
Insulation
B
001 18 Gauge Stranded 0.72 Ø 1.6-2.1 2.1
011 20 Gauge Stranded 0.60 Ø 1.6-2.1 2.1
022 22 Gauge Stranded 0.47 Ø 1.1-1.6 1.6
032 24 Gauge Stranded 0.37 Ø 1.1-1.6 1.6
SMT PCB LAYOUT
PURE TIN PADS
PACKING DETAILS
REEL QTY
LEADER
TRAILER
1000
480MM
120MM
46
SSL - Discrete Wire IDC
Series 9176
60-9176-00X-0XX-X00
ACCESSORY CAP – THROUGH WIRE
NOTES:
1. CAP FOR IDC WIRE TO BOARD CONNECTION, 2 AND 3 WAY,
THROUGH WIRE.
2. FOR USE WITH STANDARD 9176 IDC CONNECTORS, SEE
PAGE 43 FOR THE CORRECT PART CODE TO MATCH WIRE.
3. CAP MATERIAL: GLASS FILLED NYLON 46, FOR COLORS
SEE TABLE BELOW.
4. DIMENSIONS A, B AND TEXT, SEE TABLE BELOW.
5. CAPS DESIGNED TO ACCOMMODATE WIRE INSULATION
DIAMETERS 1.1MM TO 1.6MM AND 1.6MM TO 2.1MM.
6. ALL DIMENSIONS SHOWN ARE REFERENCE DIMENSIONS.
7. PACKED IN BAGS, 1000 PIECES PER BAG.
Code Slot A Diameter B
Text
9176 Ø1.6
9176 Ø2.1
Color X00
Black 000
White 100
016
021
1.60
2.10
1.00
1.50
47
SSL - Discrete Wire IDC
Series 9176
60-9176-00X-0XX-X99
ACCESSORY CAP – WIRE STOP
NOTES:
1. CAP FOR IDC WIRE TO BOARD CONNECTION, 2 AND 3
WAY, WITH WIRE STOP.
2. FOR USE WITH STANDARD 9176 IDC CONNECTORS, SEE
PAGE 43 FOR THE CORRECT PART CODE TO MATCH WIRE.
3. CAP MATERIAL: GLASS FILLED NYLON 46, FOR COLORS
SEE TABLE BELOW.
4. DIMENSIONS A, B AND TEXT, SEE TABLE BELOW.
5. CAPS DESIGNED TO ACCOMMODATE WIRE INSULATION
DIAMETERS 1.1MM TO 1.6MM AND 1.6MM TO 2.1MM.
6. ALL DIMENSIONS SHOWN ARE REFERENCE DIMENSIONS.
7. PACKED IN BAGS, 1000 PIECES PER BAG.
Code Slot A Diameter B
Text
9176 Ø1.6
9176 Ø2.1
Color X99
Black 099
White 199
016
021
1.60
2.10
1.00
1.50
48
SSL - Discrete Wire IDC
Series 9176
HAND INSERTION TOOLING
FOR SINGLE 18/24 GAUGE WIRE
UNIVERSAL HANDLE
Tool
Part Number
Details
6.35 A/F HEX
BIT HOLDER
06 7000 7730 01 000
HIGH PRODUCTION
MED PRODUCTION
Metal
Metal/Plastic
Max
Max
Tool
Tool
Insulation
Part Number
Dia
Insulation
Part Number
Dia
ꢀ 2.10
ꢀ 1.60
06 9176 7017 01 000
06 9176 7017 02 000
ꢀ 2.10
ꢀ 1.60
06 9176 7016 01 000
06 9176 7016 02 000
CLEARANCE AREA ON PCB FOR HAND TOOLING
2 WAY 3 WAY
1 WAY
49
SSL - Discrete Wire IDC
Series 9176
INSERTION TOOLING
REQUIRES HAND PRESS WITH FLAT ROCK PLATES
2 WAY
3 WAY
HIGH PRODUCTION
Metal
Max
Insulation
Dia
No.
Tool
of Ways
Part Number
ꢀ 2.10
ꢀ 1.60
ꢀ 2.10
ꢀ 1.60
06 9176 7017 01 002
06 9176 7017 02 002
06 9176 7017 01 003
06 9176 7017 02 003
2
3
2 WAY
3 WAY
NOTES:
1. DIMENSIONS SHOWN ARE REFERENCE DIMENSIONS.
2. MAXIMUM COMPONENT HEIGHT 1.00MM IN THIS AREA.
3. MAXIMUM COMPONENT HEIGHT 6.00MM IN THIS AREA.
4. THE SAME RESTRICTIONS APPLY TO ALL WIRE INSULATION DIAMETERS
5. 2 AND 3 WAY TOOLS ONLY, FOR USE UNDER HAND PRESS WITH FLAT PLATES.
6. FOR HAND TOOLING REFER TO PAGE 47.
50
相关型号:
©2020 ICPDF网 联系我们和版权申明